Product Code
4727E/13
Strainer CO2
1.5/8"ODS
PS = 120 bar - 1740 PSI
Product use
Inspectionable strainers can be installed in all lines of a refrigeration system, wherever it is necessary to avoid the accumulation of dirt or slag in very delicate components (for example in back-pressure valves).
Accessories for use with refrigerant R744.
Product Details
Connections ODS Ø [in.]
1.5/8"
Filtering surface [cm²]
46
Mesh-opening [mm]
0,2
Kv [m³/h]
10
PS [bar]
130
MWP [psi] (1)
1740
TS [°C] min.
-40
TS [°C] max.
+140
Package pcs
1
Notes where expressly stated